Plumb line is mainly used in concrete and masonry dams for measurement and monitoring of relative displacement between:
- Dam top and the base
- Base and the foundation rock
The advanced automatic readout unit with remote real time monitoring facility, comprises of two contactless inductive sensors that give position of the pendulum wire in two directions. It is very precise system providing an accuracy of 0.01 mm. Pendulums already in situ can be measured by the readout unit without additional modification. It only requires a target to be added to the pendulum wire for the device to be effective.
The readout unit is equipped with a specific temperature gage that provides proper reference when temperature compensation is required. An additional transducer for automatic compensation of the wire rotation is mounted on one of the two axes
The automatic readout system
Accuracy |
0.01 mm |
Repeatability |
0.05% fs |
Supply |
24 Vdc |
Output |
4-20 mA |
Operating temperature |
-25 to+70ºC |