This compression load cells have great resistance to extraneous forces. This increases the fatigue life, permits less stringent mounting alignment and reduces the possibility of reading error. The load cell is protected against dust, moisture and adverse environmental conditions.
Load cell readings can be measured by using any standard digital read-out unit suitable for resistive strain gage type sensors. The data can also be automatically collected at desired frequency, stored and transmitted to remote server by a suitable datalogger using multiplexer/busmux or SDI-12 digital interface logger.
Load cell type |
Resistive strain gage |
Range (kN) |
1000, 1500, 2000, 3000, 3500 |
Over range capacity |
150 % |
Non linearity |
± 1 % fs |
Output |
1.5 mV/V ± 10 % |
Excitation |
10 VDC (maximum 20 VDC) |
Terminal resistance |
Input |
770 Ohm ± 5 % |
Output |
700 Ohm ± 1 % |
Temperature limit |
-20 to 80°C |